incidents: paginate incidents

This commit is contained in:
Gregor Michels 2022-08-21 22:19:19 +02:00
parent 6e5d4448db
commit f240192bab
1 changed files with 14 additions and 14 deletions

View File

@ -2,8 +2,8 @@
Collection of all incidents
===========================
2022.06.30 17:00 - 18:00 | power issues on gw-core01
----------------------------------------------------
001: 2022.06.30 17:00 - 18:00 | power issues on gw-core01
---------------------------------------------------------
**issue**:
@ -19,8 +19,8 @@ Tape back the protective cap of the power strip and reinsert the power supply
No internet access for 2 hours
2022.06.30 12:00 - 2022.07.01 19:00 | wifi issues in tent 5
-----------------------------------------------------------
002: 2022.06.30 12:00 - 2022.07.01 19:00 | wifi issues in tent 5
----------------------------------------------------------------
### issue
@ -108,8 +108,8 @@ sys 0m0.015s
user@freifunk-admin:~$
```
2022.07.03 00:30 | (maintenance) rolling wifi channel updates
-------------------------------------------------------------
003: 2022.07.03 00:30 | (maintenance) rolling wifi channel updates
------------------------------------------------------------------
We skipped mapping every ap to non overlapping channels while installing the infrastructure because of time constraints.
@ -122,8 +122,8 @@ Either clients "roamed" (no fast roaming - short interuptions) to a different ap
For every client not more than 10-15 seconds service interruption.
2022.07.17 01:50 | (maintenance) increase dhcp pool size for clients
--------------------------------------------------------------------
004: 2022.07.17 01:50 | (maintenance) increase dhcp pool size for clients
-------------------------------------------------------------------------
The dnsmasq instance for the client network (`10.84.4.0/22`) only used the dhcp pool `10.84.4.100 - .250`.
@ -136,8 +136,8 @@ Afterwards I've reloaded `dnsmasq` on `gw-core01`.
Currently `dnsmasq` has handed out 104 leases, so we presumably never ran out of ips in the old pool.
2022.07.23 07:40 - 12:50 | power outage in tent 5
-------------------------------------------------
005: 2022.07.23 07:40 - 12:50 | power outage in tent 5
------------------------------------------------------
There was a power outage in tent 5 taking down `sw-access02` and therefore also `ap-1a38` (tent 5) and `ap-2bbf` (tent 4).
@ -151,8 +151,8 @@ Maybe we can "whitelist" certain people at the facility so they can always acces
**Update 2022.07.28**: The facility management created id cards for `@hirnpfirsich`, `@katzenparadoxon` and `@martin`
2022.07.25 01:00 | (maintenance) os upgrades
--------------------------------------------
006: 2022.07.25 01:00 | (maintenance) os upgrades
-------------------------------------------------
OS upgrades of non-customer facing machines/services
@ -164,8 +164,8 @@ OS upgrades of non-customer facing machines/services
* `eae-adp-jump01`: `syspatch && rcctl restart cron`
2022.08.01 14:00 - 2022.08.15 14:15 | no internet access
--------------------------------------------------------
007: 2022.08.01 14:00 - 2022.08.15 14:15 | no internet access
-------------------------------------------------------------
Vodafone expired theire free internet offering for refugee camps on 01.08.2022.