This repository has been archived on 2024-05-11. You can view files and clone it, but cannot push or open issues or pull requests.
gluon-firmware/patches/openwrt/0062-ar71xx-don-t-use-D-Lin...

29 lines
1.1 KiB
Diff

From: Matthias Schiffer <mschiffer@universe-factory.net>
Date: Thu, 28 Jul 2016 15:59:04 +0200
Subject: ar71xx: don't use D-Link DIR-505 status LED as ethernet indicator
The stock firmware uses the single LED as status indicator only. Using the
same LED both for status and as ethernet indicator is uncommon, and has
been confusing users who were using the device as a WLAN mesh node (so the
LED was just off, as no ethernet was connected).
Signed-off-by: Matthias Schiffer <mschiffer@universe-factory.net>
Backport of LEDE adbbfb7ff900c489e6be34b2ec2834172dff7943
diff --git a/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds b/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds
index 14aa7bc..3d240fb 100644
--- a/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds
+++ b/target/linux/ar71xx/base-files/etc/uci-defaults/01_leds
@@ -139,10 +139,6 @@ dhp-1565-a1)
ucidef_set_led_switch "wan" "WAN" "d-link:green:planet" "switch0" "0x20"
;;
-dir-505-a1)
- ucidef_set_led_netdev "lan" "LAN" "d-link:green:power" "eth1"
- ;;
-
dir-600-a1|\
dir-615-e1|\
dir-615-e4)